- Home
- Programs
- Engineering Services (DES)
- Authorized Materials Lists (AML)
- Prestress/Post-Tensioning Strand Systems
Prestress/Post-Tensioning Strand Systems
Stresstek
S7.5P
Last edit date: 3/20/2024
GENERAL |
| Bar or Tendon Size |
Strand Diamter |
Ultimate (kips) |
Concrete Strength(psi) |
PJack (kips) |
| 7 |
1/2" |
289.1 |
N/A |
217 |
WEDGES |
| Wedges Length |
Material |
Wedge Parts |
Wedge Angle |
Wedge Inside Diameter |
| 1.85" |
AISI 86L20 Rc 59-62 | |
7° 10' |
|
| 1.85" |
AISI C11L17 Rc 59-62 | |
7° 10' |
|
ANCHOR HEADS |
| Anchor Heads Size |
Material |
Authorization Date |
| 8" x 9" x 1 3/4" |
AISI C1040/C1050 | 1/9/1981 |
Wedge hole angle: 7° Wedge hole diameter: 0.970" Strand hole diameter: 0.570" |
BEARING PLATES |
| Bearing Plates Size |
Material |
Authorization Date |
| Integral |
AISI C1040/C1050 | 1/9/1981 |
Bearing hole diameter: Spiral size and turns: none
|
TRUMPETS |
| Trumpets Size |
Material |
Authorization Date |
| 12" |
16 Gage | 1/9/1981 |
| 12" |
16 Gage | 2/4/1981 |
DUCTS |
| Ducts Size |
Material |
Authorization Date |
| 2 1/4" O.D. |
| |