Prestress/Post-Tensioning Strand Systems
Schwager Davis Incorporated
SDI 2.6A (Epoxy)
Last edit date: 3/20/2024
GENERAL |
|||||||
| Bar or Tendon Size | Strand Diamter | Ultimate (kips) | Concrete Strength(psi) | PJack (kips) | |||
|---|---|---|---|---|---|---|---|
| 2 | 0.6" | 234 | 3500 | N/A | |||
WEDGES |
|||||||
| Wedges Length | Material | Wedge Parts | Wedge Angle | Wedge Inside Diameter | |||
|---|---|---|---|---|---|---|---|
| 1.81" | AISI 12L14 | 3 | 7° | ||||
| 1.81" | AISI 11L17 | 3 | 7° | ||||
ANCHOR HEADS |
|||||
| Anchor Heads Size | Material | Authorization Date | |||
|---|---|---|---|---|---|
| 3.25" x 6.75" x 2.0" | A536 Gr.80-55-06 | 8/21/2012 | |||
Wedge hole angle: Wedge hole diameter: Strand hole diameter: | |||||
BEARING PLATES |
|||||
| Bearing Plates Size | Material | Authorization Date | |||
|---|---|---|---|---|---|
| 4.375" x 1.8125" x 2.5625" | Grout Cap - Nylon 6, G.F. Black | 8/21/2012 | |||
Bearing hole diameter: Spiral size and turns: |
|||||
TRUMPETS |
|||||
| Trumpets Size | Material | Authorization Date | |||
|---|---|---|---|---|---|
| 8.0" | HDPE | 8/21/2012 | |||
DUCTS |
|||||
| Ducts Size | Material | Authorization Date | |||
|---|---|---|---|---|---|
| 2" Ø round | metal | ||||
SPIRAL |
|
| NOTES: Local zone reinforcement: 2 pairs of #3 stirrups (4 total) | |