Prestress/Post-Tensioning Strand Systems

Schwager Davis Incorporated

SDI 12.6-PC

Last edit date: 3/20/2024

GENERAL

Bar or Tendon Size Strand Diamter Ultimate (kips) Concrete Strength(psi) PJack (kips)
12 0.6" 703 3500 527

WEDGES

Wedges Length Material Wedge Parts Wedge Angle Wedge Inside DiameterBABA Act Information*
1.77" AISI 12L142 Unconfirmed
1.77" AISI 11L172 Unconfirmed

ANCHOR HEADS

Anchor Heads Size Material Authorization DateBABA Act Information*
7.06" O.D. x 5.2" shldr x 3" depth ASTM A536 Grade 80-55-06Unconfirmed
Wedge hole angle:
Wedge hole diameter:
Strand hole diameter:

BEARING PLATES

Bearing Plates Size Material Authorization DateBABA Act Information*
11.50" O.D. x 5.5" I.D. x 3" depth ASTM A 536 Grade 80-55-06Unconfirmed
Bearing hole diameter:
Spiral size and turns:

TRUMPETS

Trumpets Size Material Authorization DateBABA Act Information*
14" x 5 7/16" O.D. x 3 3/8" I.D. HDPEUnconfirmed

DUCTS

Ducts Size Material Authorization DateBABA Act Information*
3" I.D. Unconfirmed

SPIRAL

#4 Spiral @13" OD 6 turns @ 3" Pitch

Caltrans contact: Jim Ma, Concrete Committee Chair, jim.ma@dot.ca.gov

*As attested to by the supplier as of April 14, 2026 per definition in 2 CFR 184 and 23 CFR 635.410. Stakeholders should use this information in conjunction with corresponding Caltrans special provision section 6-1.04 to understand applicable requirement for the project.

The California Department of Transportation (Caltrans) is implementing statutory changes required by the Bipartisan Infrastructure Law -Build America, Buy America Act (BABA), as outlined in 2 CFR 184 and 23 CFR 635.410.

https://www.fhwa.dot.gov/construction/cqit/buyam.cfm