Prestress/Post-Tensioning Strand Systems

Avar Construction Systems, Incorporated

C4.6

Last edit date: 3/20/2024

GENERAL

Bar or Tendon Size Strand Diamter Ultimate (kips) Concrete Strength(psi) PJack (kips)
4 0.6" 234.4 3500 176

WEDGES

Wedges Length Material Wedge Parts Wedge Angle Wedge Inside Diameter
1.80" AISI 11L17 RA 79-83 7° 10'

ANCHOR HEADS

Anchor Heads Size Material Authorization Date
3 1/8" x 4 1/4" x 2 1/2" ASTM A-536 80-55-068/22/1989
Wedge hole angle:
Wedge hole diameter: 1.16"
Strand hole diameter: 0.70"

BEARING PLATES

Bearing Plates Size Material Authorization Date
4 5/8" x 10.5" x 5/16" ASTM A-536 80-55-068/22/1989
Bearing hole diameter: 1 7/8" x 3 3/8"
Spiral size and turns: none

TRUMPETS

Trumpets Size Material Authorization Date
There are no trumpet components for this system at this time

DUCTS

Ducts Size Material Authorization Date
4" I.D.

SPIRAL

-