Prestress/Post-Tensioning Strand Systems

Contech

4-0.6 (using 7-0.6 anchor)

Last edit date: 3/20/2024

GENERAL

Bar or Tendon Size Strand Diamter Ultimate (kips) Concrete Strength(psi) PJack (kips)
4 0.6" 234.4 3500 176

WEDGES

Wedges Length Material Wedge Parts Wedge Angle Wedge Inside DiameterBABA Act Information*
1.875" AISI 12L14 Rc 59-653 7° 10' ± 10' 0.620" x 4°Unconfirmed

ANCHOR HEADS

Anchor Heads Size Material Authorization DateBABA Act Information*
5 1/8" Ø x 2 3/8" Ductile Iron ASTM A-536-80-55-064/20/1992Unconfirmed
Wedge hole angle:
Wedge hole diameter: 1.250"
Strand hole diameter: 0.62"

BEARING PLATES

Bearing Plates Size Material Authorization DateBABA Act Information*
7" x 7" x 11/2"(Restrainer Plate) A-364/20/1992Unconfirmed
Bearing hole diameter: 4"
Spiral size and turns: none

TRUMPETS

Trumpets Size Material Authorization DateBABA Act Information*
There are no trumpet components for this system at this time

DUCTS

Ducts Size Material Authorization DateBABA Act Information*
There are no duct components for this system at this time

SPIRAL

-

Caltrans contact: Jim Ma, Concrete Committee Chair, jim.ma@dot.ca.gov

*As attested to by the supplier as of April 14, 2026 per definition in 2 CFR 184 and 23 CFR 635.410. Stakeholders should use this information in conjunction with corresponding Caltrans special provision section 6-1.04 to understand applicable requirement for the project.

The California Department of Transportation (Caltrans) is implementing statutory changes required by the Bipartisan Infrastructure Law -Build America, Buy America Act (BABA), as outlined in 2 CFR 184 and 23 CFR 635.410.

https://www.fhwa.dot.gov/construction/cqit/buyam.cfm