- Home
- Programs
- Engineering Services (DES)
- Authorized Materials Lists (AML)
- Prestress/Post-Tensioning Strand Systems
Prestress/Post-Tensioning Strand Systems
Avar Construction Systems, Incorporated
AVAR ACS-22.6
Last edit date: 3/20/2024
GENERAL |
Bar or Tendon Size |
Strand Diamter |
Ultimate (kips) |
Concrete Strength(psi) |
PJack (kips) |
22 |
0.6" |
1289 |
3500 Lt.Wt. |
968 |
WEDGES |
Wedges Length |
Material |
Wedge Parts |
Wedge Angle |
Wedge Inside Diameter |
1.81" |
| |
7° |
0.63" |
ANCHOR HEADS |
Anchor Heads Size |
Material |
Authorization Date |
9.02" x 4.25" |
A536 GR. 80-55-06 | 10/7/2002 |
Wedge hole angle: Wedge hole diameter: 1.18" Strand hole diameter: 0.87" |
BEARING PLATES |
Bearing Plates Size |
Material |
Authorization Date |
17.25" x 16.25" x 3" |
A536 GR. 80-55-06 | 10/7/2002 |
Bearing hole diameter: 7.05" Spiral size and turns: none
|
TRUMPETS |
Trumpets Size |
Material |
Authorization Date |
18" x 7" |
HDPE | |
DUCTS |
Ducts Size |
Material |
Authorization Date |
108mm |
Galvanized Spiro | |