Prestress/Post-Tensioning Strand Systems

Avar Construction Systems, Incorporated

AVAR C-4.6

Last edit date: 3/20/2024

GENERAL

Bar or Tendon Size Strand Diamter Ultimate (kips) Concrete Strength(psi) PJack (kips)
4 0.6" 234 3500 Lt.Wt. 176

WEDGES

Wedges Length Material Wedge Parts Wedge Angle Wedge Inside Diameter
1.81" AISI 12L14 0.63"
1.81" AISI 11L17 0.63"

ANCHOR HEADS

Anchor Heads Size Material Authorization Date
10.5" x 4.61" x 2.52" A536 Gr. 80-55-069/27/2002
Wedge hole angle:
Wedge hole diameter:
Strand hole diameter: 0.71"

BEARING PLATES

Bearing Plates Size Material Authorization Date
There are no bearing plate components for this system at this time
Bearing hole diameter:
Spiral size and turns: none

TRUMPETS

Trumpets Size Material Authorization Date
HDPE

DUCTS

Ducts Size Material Authorization Date
25 x 75 mm galvanized spiro duct

SPIRAL

-