- Home
- Programs
- Engineering Services (DES)
- Authorized Materials Lists (AML)
- Prestress/Post-Tensioning Strand Systems
Prestress/Post-Tensioning Strand Systems
Avar Construction Systems, Incorporated
ACS 44.5
Last edit date: 3/20/2024
GENERAL |
| Bar or Tendon Size |
Strand Diamter |
Ultimate (kips) |
Concrete Strength(psi) |
PJack (kips) |
| 44 |
1/2" |
1817.2 |
3500 |
1363 |
WEDGES |
| Wedges Length |
Material |
Wedge Parts |
Wedge Angle |
Wedge Inside Diameter |
| 1.46" |
AISI 11L17 Rc 59-63 | 2 |
7° 10' |
|
ANCHOR HEADS |
| Anchor Heads Size |
Material |
Authorization Date |
| 11" Square x 5 1/2" |
C1040-1045 H.R. Plate | 9/1/1993 |
Wedge hole angle: 7° Wedge hole diameter: 1.035" Strand hole diameter: 0.63" |
BEARING PLATES |
| Bearing Plates Size |
Material |
Authorization Date |
| 21" Square x 3" |
ASTM A-36 | 9/1/1993 |
Bearing hole diameter: 8.875" Spiral size and turns: none
|
TRUMPETS |
| Trumpets Size |
Material |
Authorization Date |
| 20" |
| 9/1/1993 |
DUCTS |
| Ducts Size |
Material |
Authorization Date |
| 5" O.D. |
| 9/1/1993 |