- Home
- Programs
- Engineering Services (DES)
- Authorized Materials Lists (AML)
- Prestress/Post-Tensioning Strand Systems
Prestress/Post-Tensioning Strand Systems
Avar Construction Systems, Incorporated
ACS 27.6"
Last edit date: 3/20/2024
GENERAL |
Bar or Tendon Size |
Strand Diamter |
Ultimate (kips) |
Concrete Strength(psi) |
PJack (kips) |
27 |
0.6" |
1582.2 |
3500 |
1188 |
WEDGES |
Wedges Length |
Material |
Wedge Parts |
Wedge Angle |
Wedge Inside Diameter |
1.80" |
AISI 12L14 | 2 |
6° 55' ± 10' |
0.62" |
1.80" |
AISI 11L17 | 3 |
6° 55' ± 10' |
0.62" |
1.80" |
AISI 12L14 | 3 |
6° 55' ± 10' |
0.62" |
1.80" |
AISI 11L17 | 3 |
6° 55' ± 10' |
0.62" |
ANCHOR HEADS |
Anchor Heads Size |
Material |
Authorization Date |
9 5/8" Ø. x 4 3/8" |
ASTM-A 536 Gr 80-55-06 | 2/27/2001 |
Wedge hole angle: 6° 55' ± 10' Wedge hole diameter: 1.16" Strand hole diameter: 0.877" |
BEARING PLATES |
Bearing Plates Size |
Material |
Authorization Date |
19fl" sq. x 3fl" |
ASTM-A 536 Gr 80-55-06 | 2/27/2001 |
Bearing hole diameter: 7 13/16" Spiral size and turns: none
|
TRUMPETS |
Trumpets Size |
Material |
Authorization Date |
19" |
HDPE | |
DUCTS |
Ducts Size |
Material |
Authorization Date |
4.375" I.D. |
| |