Prestress/Post-Tensioning Strand Systems

Avar Construction Systems, Incorporated

ACS 19 M.5"

Last edit date: 3/20/2024

GENERAL

Bar or Tendon Size Strand Diamter Ultimate (kips) Concrete Strength(psi) PJack (kips)
19 1/2" 784.7 3500 588.5

WEDGES

Wedges Length Material Wedge Parts Wedge Angle Wedge Inside Diameter
1.46" AISI 11L17 7° 10'

ANCHOR HEADS

Anchor Heads Size Material Authorization Date
7.00" Ø x 3 1/4" C 1040-1045 H.R BAR3/23/1994
Wedge hole angle:
Wedge hole diameter: 1.035"
Strand hole diameter: 0.625"

BEARING PLATES

Bearing Plates Size Material Authorization Date
13.750" Square x 3.00" ASTM-A536 Gr 80-55-063/23/1994
Bearing hole diameter: 5 1/2"
Spiral size and turns: none

TRUMPETS

Trumpets Size Material Authorization Date
13.00" 3/23/1994

DUCTS

Ducts Size Material Authorization Date
There are no duct components for this system at this time

SPIRAL

-