Prestress/Post-Tensioning Strand Systems

Avar Construction Systems, Incorporated

ACS 10.5 TD

Last edit date: 3/20/2024

GENERAL

Bar or Tendon Size Strand Diamter Ultimate (kips) Concrete Strength(psi) PJack (kips)
10 1/2" 413 3500 309.8

WEDGES

Wedges Length Material Wedge Parts Wedge Angle Wedge Inside Diameter
1.46" AISI 11L17 Rc 59-63 7° 10' ± 5'

ANCHOR HEADS

Anchor Heads Size Material Authorization Date
6" Square x 2 1/2"(w/4 hole ) C1040-1045 H.R. Plate9/26/1994
Wedge hole angle:
Wedge hole diameter: 1.00"
Strand hole diameter: 0.62"

BEARING PLATES

Bearing Plates Size Material Authorization Date
13" Square x 2 1/4" ASTM A-369/26/1994
6" Square x 1 3/4"(Ret Plate) ASTM A-369/26/1994
Bearing hole diameter: 4 1/2"
Spiral size and turns: none

TRUMPETS

Trumpets Size Material Authorization Date
There are no trumpet components for this system at this time

DUCTS

Ducts Size Material Authorization Date
There are no duct components for this system at this time

SPIRAL

-