Prestress/Post-Tensioning Strand Systems
VSL
EC5-7
Last edit date: 3/20/2024
GENERAL |
Bar or Tendon Size |
Strand Diamter |
Ultimate (kips) |
Concrete Strength(psi) |
PJack (kips) |
7 |
1/2" |
289.1 |
N/A |
217 |
WEDGES |
Wedges Length |
Material |
Wedge Parts |
Wedge Angle |
Wedge Inside Diameter |
1.570" |
AISI 86L20 Rc 59-62 | |
7° |
|
ANCHOR HEADS |
Anchor Heads Size |
Material |
Authorization Date |
4 1/2" Ø x 2.562" |
ASTM- A536 Gr 80-55-06 | 6/3/1988 |
Wedge hole angle: Wedge hole diameter: Strand hole diameter: 0.57" |
BEARING PLATES |
Bearing Plates Size |
Material |
Authorization Date |
There are no bearing plate components for this system at this time |
Bearing hole diameter: Spiral size and turns: none
|
TRUMPETS |
Trumpets Size |
Material |
Authorization Date |
There are no trumpet components for this system at this time |
DUCTS |
Ducts Size |
Material |
Authorization Date |
There are no duct components for this system at this time |